Appendix EMessages
The messages a technician meets most, in the program's own words, by area. For each: where it shows, what it means, and the chapter that explains what to do. Setup's own messages are in 2.12 When installation stumbles.
E.1 Signing in and the server
| The message | Where | What it means | See |
|---|---|---|---|
| You signed in without a password. Give the administrator a password, so that nobody else signs in by this button; the server is not opened to the network's devices before it. | At the top of every screen | The administrator has no password yet. The server is not opened to the network before it has one | 11.1 The first administrator |
| The licence could not be read. | Licence | The program could not read the licence's state | 3.5 When work stops |
| The licence could not be checked. | Licence | The online check of the licence did not finish. The internet, or the supplier's server | 3.3 Activating the licence |
| The update service could not be reached. | Licence | The update service could not be reached | 9.5 The log and failures |
| The licence could not be moved. | Licence | Moving the licence did not finish. The program still works on this computer | 3.4 Moving the licence to another computer |
| The request file could not be made. | Licence | The activation request file for activating without the internet could not be written | 3.3 Activating the licence |
E.2 The network and the member computers
| The message | Where | What it means | See |
|---|---|---|---|
| This computer is not connected to the laboratory's network. Connect it by cable or Wi-Fi, then check. | The laboratory's network | The server has no network | 5.2 Opening the server to the laboratory's network |
| Windows classes this network as public, so its firewall keeps the devices out. Make it private on this computer. | The laboratory's network | The network is public, so the firewall keeps the devices out | 5.2 Opening the server to the laboratory's network |
| The certificate names an address this computer no longer has. Renew it, then start again; the devices keep trusting it. | The laboratory's network | The server's address changed | 5.2 Opening the server to the laboratory's network |
| Windows did not apply the change: the approval was declined. | The laboratory's network | Windows' approval window was answered "No", or not answered | 5.8 When the network or the link stumbles |
| Windows did not apply the change: an error occurred while applying it. | The laboratory's network | Windows failed to apply the firewall's change | 5.8 When the network or the link stumbles |
| No device joins before the server is opened to the laboratory's computers. | Branch devices | The server is not opened to the network yet | 5.2 Opening the server to the laboratory's network |
| This server was opened to the computers before its number was activated, so the branch's computers cannot find it on the network yet. | Branch devices | The rule that lets members find the server is missing | 5.8 When the network or the link stumbles |
| Windows classes this computer's network as public, so its firewall keeps the branch's computers out. | Branch devices | The server's network is public | 5.8 When the network or the link stumbles |
| This device's state could not be read. Restart the program on it. | This device, on the member | The program on the member computer does not answer | 5.3 Joining a member computer |
| Joining the branch failed. | Join the branch, on the member | Joining did not succeed. Check the number, that the server allowed it, and that the server is opened to the network | 5.3 Joining a member computer |
E.3 Clarus Link
| The message | What it means | See |
|---|---|---|
| Clarus Link is not enabled for this laboratory. Contact us to enable it. Access through the laboratory's own address, where it is set up, is not affected. | The service is not enabled for the laboratory | 5.6 Clarus Link |
| Clarus Link does not recognise this copy yet. It must reach the update server at least once, and an activated copy must verify its licence online. | The copy has not reached the supplier yet | 5.6 Clarus Link |
| Clarus Link already serves another copy of the program that holds this laboratory's identity, so this copy was turned away. Run the laboratory's program on one computer only. Access through the laboratory's own address, where it is set up, is not affected. | The laboratory's program runs on two computers | 5.6 Clarus Link |
E.4 Backups
| The message | Where | What it means | See |
|---|---|---|---|
| No backup yet | Backups | No backup has been taken on this server | 8.3.2 The list of backups |
| Not met: no recent backup | Backups | The last backup is older than the laboratory allows | 8.3.1 The four facts |
| not encrypted | Backups | The backups are kept without encryption | 8.1 How the program saves the laboratory |
| Verification failed | Backups | A backup's file does not match its signature. Do not restore from it | 8.4 Verification and the restore drill |
| Restore drill failed | Backups | The last restore drill did not succeed | 8.4.2 The restore drill |
| The drill finished, and the restored copy did not match what was recorded when it was taken. | Backups | The restored copy differs from the backup's record | 8.4.2 The restore drill |
E.5 Analysers
| The message | Where | What it means | See |
|---|---|---|---|
| Not mapped | Test codes | A code the analyser sends is joined to no test, so its results are not filed | 6.4 Mapping the analyser's codes to tests |